AC MAINS

Input Power: 22VA, 115 VAC
   
Operating Range: 108-122/216-244 VAC, 50/60 Hz

INPUTS

Analog:

Nominal input level (APL):
-24 dBu, minimum

Impedance:
600 Ohms as shipped, balanced
30K (internal option), balanced

Connectors:
XL-3 Female

   
Digital:

Format:
AES3-id, transformer coupled

Sample rate:
32-48 KSPS (auto sample rate converter)

Word length:
24 bit max (internal I2S)

Connector:
BNC

Selection:
Valid digital input is taken. Invalid or no digital input takes analog input. An internal jumper can force analog selection.

OUTPUTS

Analog

Nominal output level (peak, with control):
+10 dBu, +10 dBm/600 Ohms

Maximum output level (peak):
+18 dBu, +18 dBm/600 Ohms

Adjustment range:
20 dB

Source impedance:
<50 Ohms, balanced & floating

Connectors:
XL-3 Male

   
Digital:

Format:
AES3-id, transformer coupled

Sample rate:
48 KSPS

Word length:
24 bit

Connector:
BNC

GAIN CONTROL

Overall static gain (ctl off):

Analog:
Adjustable

Digital:
10.6 dB

Processing gain with respect to static gain:
+10 dB max
-10 dB min indicated
approx -20dB possible

Assumed digital APL:
-16.4 dBFS on input

Range of threshhold adjustment:
3dB

ADAPTIVE PRE-EMPHASIS CONTROL
(This is an internally jumper selected control option.)

Time constant: 75 microseconds
   
Inflection frequency of control: Variable
   
Range of threshold adjustment: 0-6dB above wideband
   
FIXED OUTPUT DE-EMPHASIS
(This is an internally jumper selected option.)
   
Time constant: 75 microseconds
   
METER INDICATIONS
   
Input: L only with 10dB peak marker
R only with 10dB peak marker
L&R together
   
Output: L only with +10dBu marker
R only with +10dBu marker
L&R together
   
Level matching: Log peak of Input (L-R)
Log peak of Output (L-R)
   
Wideband AGC: Operating gain over range of
+10 to —10 dB
   
Adaptive pre-emphasis (HFL): High frequency gain (15kHz)
From 0dB to approx —17 dB
   
Messages: HFL not enabled
Digital input selected
Pre-emphasis enabled
   
Alarm: Input polarity reversed

MECHANICAL

Mounting EIA 19" rack, 1U high
   
Depth 16"(406mm) plus connectors
   
Weight Approx 6 kg (13 lbs)

ELECTRICAL PERFORMANCE
Frequency Response

Digital input to Analog or digital output: +/-0.5dB, 30Hz-14kHz
   
Analog input to Analog or Digital output: +/-0.5dB, 50Hz-14kHz
   
Analog input high-pass filter: -3dB at 30 z/18dB/oct
(The HPF can be bypassed)

Notes: The unit incorporates a 15.7kHz notch filter and BTSC system alias protection LPF. These filters are always present in both the analog and digital input paths

The same tolerance is met when the HFL is engaged along with the fixed output de-emphasis option, with control off. With control on, the input level must be reduced below the HFL theshhold, in which case the tolerance is also met.

With HFL engaged and no output de-emphasis, the 75usec pre-emphasis is accurate to a smaller tolerance (typically +/-0.2 dB), with control off or at level below HFL threshold.

(THD+noise): Either input to Digital output at -1dBFS <0.1%, 30Hz-14kHz
Either input to Analog output at +10dBu <0.1%, 30Hz-14kHz

Crosstalk: Analog inputs to either outputs >50dB, <10kHz
Digital inputs to either outputs >55dB, <10kHz

Output noise: Either inputs to Digital out -83dBFS
Either inputs to Analog out -72dBu