DIMENSIONS
Inches (mm)

FRONT PANEL:
3.5 (88.9) H x 19 (482.6) W

CHASSIS:
3.5 (88.9) H x 16.75 (425.5) W x 9.25 (235) D

   
POWER 95 to 130 VAC, 50/60 Hz, 12 W maximum
190 to 260 VAC option available
   
TEMPERATURE RANGE 0° to 50° C.
   
RF PROTECTION All inputs and outputs RF suppressed; power supply RF suppressed and shielded from main circuitry.
   
CONTROLS See block diagram above
 
CONNECTORS/LEVELS/IMPEDANCES
   
AUDIO IN: No. 6 screw terminals
-30 to +10 dBm
600 Ohm resistive ±2%
   
REMOTE CONTROL: No. 6 screw terminals
6 to 24 VAC, 10 to 24 VDC
   
COMPOSITE IN: BNC connector
Unity gain to composite output
10 kOhm unbalanced
   
COMPOSITE OUT: BNC connector
Stereo level 0.4 to 4 V P-P
Subcarrier level 0.04 to 0.4 V P-P
Noise test level 0.4 to 4 V P-P
50 Ohm output impedance
600 Ohm minimum load impedance
   
SUBCARRIER OUT: BNC connector
0.35 to 3.5 V P-P
50 Ohm output impedance
600 Ohm minimum load impedance
   
TELEMETRY IN: BNC connector
3.5V P-P = ± 500 Hz deviation
10 kOhm
   
RF IN: BNC connector
0.1 to 2W
50 Ohm
   
FREQUENCY RESPONSE (Note 1) -3 dB @ 50 Hz and 5 kHz
±1 dB 70 Hz to 4 kHz
   
NOISE (Note 2) 65 dB below 5 kHz deviation
   
FREQUENCY ACCURACY ±0.01% at 25°C.
   
FREQUENCY DRIFT
±0.005% from 0° to 50°C.
 

SPURIOUS COMPONENTS (NOTE 3)

2nd HARMONIC:
better than 40 dB below subcarrier.

3rd HARMONIC:
better than 45 dB below subcarrier.

   
ALL OTHER COMPONENTS, 50HZ TO 100 KHZ:
Better than 60 dB below subcarrier.
   
CARRIER SUPPRESSION WHEN MUTED Better than 50 dB below subcarrier.
   
MUTING LEVEL Adjustable from 10 to 30 dB below peak deviation set by "DEV" control. See block diagram, "Broadband Limiter."
   
MUTING DELAY Selectable from 300 ms to 6 seconds.
   
METER CIRCUIT

Peak deviation:
±5% accuracy

Synchronous AM :
-20 to -60 dB sensitivity
Ref. 100% AM modulation

 
NOTES
 

Note 1:
Measured with signal below compression threshold

Note 2:
Measured with 150 µs preemphasis (generator) and deemphasis (receiver)

Note 3:
Relative to 100% total modulation at 10% Subcarrier injection; 60, 65 and 80 dB respectively.