DIMENSIONS Inches (mm)
1.75 (44.5) H x 19 (482.6) W x 5.75 (146.1) D

   
POWER 95 to 130 VAC, 50/60 Hz, 10 W maximum
90 to 260 VAC option available (please specify when ordering)

   
TEMPERATURE RANGE 0 to 50 degrees C.
   
RF PROTECTION All inputs and outputs RF suppressed; power supply RF Suppressed and shielded from main circuitry.
   
GAIN CONTROLS The input and output controls are used to set levels and control the amount of limiting.
   
PILOT TRIM The plot filter trim controls are preset at the factory, They should be checked yearly according to the procedure in the Technical Manual.
   
INDICATORS

Power:
Green LED

Norm:
Yellow LED – indicates that signal has exceeded limiting threshold.

OL:
Red LED – indicates that limiting duty cycle is excessive.

   
CONNECTORS Input: BNC connector
   
LEVELS 0.5 to 4 volts PP
   
IMPEDANCES 22 kOhms Output: BNC connector 0.5 to 4 volts PP 50 to 250 Ohms (depending on output gain setting)
Minimum load impedance 500 Ohms
Pilot Test: RCA jack – used for alignment of pilot filter

   
TEST CONDITIONS FOR THE FOLLOWING SPECIFICATIONS

Input and output levels:
1 volt PP

Input frequency range:
50 Hz to 15 kHz and 23 to 53 kHz

Source impedance:
0 to 1 kOhm

Load impedance:
10 kOhm shunted by 100 p

Temperature:
0 to 50 degrees Centigrade
Threshold of limiting set to 100% modulation

   
FREQUENCY RESPONSE ± 0.03 dB referenced to 1 kHz
   
HARMONIC DISTORTION 0.02% maximum at 95% modulation
   
IM DISTORTION 70 dB below 100% modulation, tested with any
two frequencies in input frequency range, 1:1 at 95% peak modulation

   
DIFFERENTIAL PHASE 0.1 degree maximum, 19 to 38 kHz
PHASE 0.2 degree maximum, 15 to 53 kHz

   
WIDEBAND NOISE 75 dB below 100% modulation, measured 20 Hz to
100 kHz, unweighted

   
STEREO PERFORMANCE AT 100% MODULATION (note 1)

Crosstalk (note 2):
Main to Sub:
more than 40 dB below 90% modulation
AT 100%

Sub to Main:
more than 40 dB below 90% modulation

Stereo Separation:
400 Hz: better than 48 dB
15 kHz: better than 36 dB

Harmonic Distortion (note 3):
50 to 100 Hz:
less than 0.4%

100 Hz to 7.5 kHz:
less than 0.5%

7.5 to 15 kHz:
less than 1.5%

   
PILOT MODULATION Varies less than 0.2% up to 6 dB of limiting
 

NOTES:

  1. These figures are for the entire stereo generator/Composite Processor/transmitter system. It is assumed that the system was within the limitations of FCC Rules before installation of the CP-803. All figures are typical.
  2. Systems having nonlinear crosstalk of worse than –45 dB before installation of the CP-803 may not meet these specifications at all frequencies.
  3. All noise and distortion components from 20 Hz to 80 kHz were measured.